R 449a Pt Chart
Continue

R 449a Pt Chart

net>Opteon™ XP40 Pressure. com Barcelona - Madrid - Zaragoza - Mexico City 2 TECHNICAL DATA SHEET R-449A Mollier Diagram. REFRIGERANT CHANGEOVER HFC R404A OR R507 TO …. Use the vapor column for calculating superheat and the liquid column for subcooling. RSD Mobile - PT Chart - R449A Molecular Weight; 87. R290 Pressure Temperature Chart. RSD Mobile - PT Chart - R449A Molecular Weight; 87. PT charts for the zeotropic blends list two columns next to each temperature: one for the saturated liquid (bubble point) and the other for the saturated vapor (dew point). R-449A (XP40) is an HFO-based refrigerant blend that was initially developed as a replacement for high GWP HFC blends like R-404A/R-507, but now is being investigated as a potential R-22 alternative in refrigeration applications as well. Pressure Temperature Chart: R-449A Best for use in: Used in low and medium temperature commercial refrigeration systems to replace R-22, R-404A, or R-507. Opteon™ XP40 Pressure-Temperature Data (Eng) P (psig ) Sat Liq T (°F) Sat Vap T (°F) P (psig ) Sat Liq T (°F) Sat Vap T (°F) P (psig ) Sat Liq T (°F) Sat Vap T (°F)-4. It has a GWP of 1273 and provides 68% GWP reduction compared to R404A. Scroll down to find download buttons for pressure enthalpy charts in either Metric or Imperial Units. REFRIGERANT CHANGEOVER HFC R404A OR R507 TO HFC. PT Chart Index Charts use °F and psig. R-449A XP40 Opteon Refrigerant PT Chart April 21, 2020 by Alec Johnson One of the very first steps when it comes to diagnosing your home air conditioner, refrigerator, or even your vehicles air conditioner is understanding the temperature and the current pressure that your system is operating at. Freon™ MO29 (R-422D) refrigerant is a low-toxicity, non-ozone depleting hydrofluorocarbon (HFC) replacement for R-22. R-449A Pressure Temperature. R449A Pressure Enthalpy Chart. R-449A will have similar capacity to R-404A (or similar) refrigerants. It’s calculated as Gauge Pressure + Atmospheric Pressure. R-449A Pressure Temperature. A Next-Generation R-134a Refrigerant Alternative. Pressure Temperature (P/T) Chart: All refrigerants have a respective P/T chart. Temp (°F) Pressure Temp (°C) Temp (°F) Pressure Temp (°C) Temp (°F) Temp (°C) Pressure Temp (°F) Pressure Temp (°C). 18 PRESSURE (PSIG) Sat. R410A Pressure-Temperature Chart For Degrees Of Celsius (°C) As you can, the pressure at a specific temperature is usually given in 3 different units: barA. If you look at a PT chart, the relationship is much closer between these refrigerants, compared to 404/507. R-448A N40 Refrigerant PT Chart. Pressure / temperature table www. HCFCs Compounds containing hydrogen, fluorine, chlorine, and carbon atoms. Forane® Refrigerant Pressure Temperature Chart. PSIG TEMPERATURE °F REFRIGERANT - (Sporlan Code) 410A (Z) 438A (V) 448A (D) 449A (D) 507 (P) 513A (J) Bubble Point Dew Point Bubble Point Dew Point Bubble Point Dew Point Bubble Point Dew. Opteon™ XP40 (R-449A) refrigerant is an environmentally sustainable, non-ozone depleting refrigerant offering a low global warming potential (GWP) and a superior R-507 replacement. Refrigerant changeover guidelines. It has a GWP of 1273 and provides 68% GWP reduction. R-513A is intended for use in low and medium temperature refrigeration systems to replace R-22 and R-404A. R22 Pressure-Temperature Chart-49-45: 1-17. Although ozone depleting substances, they are less potent at destroying stratospheric ozone than chlorofluorocarbons (CFCs). Pressure Temperature Chart: R-449A Best for use in: Used in low and medium temperature commercial refrigeration systems to replace R-22, R-404A, or R-507. ‎HVACR Check & Charge on the App Store. R-449A CHEMICAL PRODUCT AND COMPANY IDENTIFICATION PRODUCT NAME: OTHER NAME:USE:DISTRIBUTOR: R-449A Refrigerant 449A Refrigerant National Refrigerants, Inc. R-449A – Blend of R-134a, R-1234yf, R-125, and R-32 GWP of 1,282. To learn more about the retrofitting process, visit r22retrofits. R449A (XP40) Pressure Temperature Chart. Opteon™ XL refrigerants provide very low GWP solutions that are specifically developed to enable new, energy efficient equipment. R-449A Refrigerant Safety Data Sheet R-449A 1. R-404A, and R-452A are non-flammable. R-449A XP40 Opteon Refrigerant PT Chart April 21, 2020 by Alec Johnson One of the very first steps when it comes to diagnosing your home air conditioner, refrigerator, or even your vehicle’s air conditioner is understanding the temperature and the current pressure that your system is operating at. • PT Charts (Pressure / Temperature) • Find a Superheat target using psychometric calculations • For use with R-22, R-410A, R-32, R-407C, R-134a, R-452B, R-454B, R-438A, R-422B, R-427A, R-421A, R-404A, R-290, R-449A, R-448A, and R-407A • Imperial and Metric Support. R-449A 4 Solstice N40 (R-448A) provides better capacity* than R-449A 4 Due to lower Tdis at the conditions shown, Solstice N40 (R-448A)does not require liquid injection in low temperature applications – unlike R-407F and R-407A -10oC-10oC / /45oC 45oC -10oC-10oC / /45oC 45oC -30oC-30oC / /45oC 45oC. Traditional PT charts list the saturated. This nonflammable HFC alternative offers a host of benefits that include: Cost-effective retrofits (and easier retrofitting) than R-404A, R-507, and R-407C A 30% lower GWP vs. We use gauge meter to measure the pressure of R404A refrigerant at different temperatures. R-449A (XP40) is an HFO-based refrigerant blend that was initially developed as a replacement for high GWP HFC blends like R-404A/R-507, but now is being investigated as a potential R-22 alternative in refrigeration applications as well. 2 lb/lb mole) Boiling Point at 101. TECHNICAL DATA SHEET R-449A Physical properties According to IPPCC-AR4/CIE (Fourth Assessment Report of the Intergovernmental Panel of Experts on Climate Change)-2007. Forane ® 427A (R427A) is the ideal R22 retrofit for air conditioning, heat pumps, and refrigeration applications. R-449A XP40 Opteon Refrigerant PT Chart. We recently changed a R404A rack (3 pieces of 6 cylinder Bitzer compressors) to R449A without changing the Thermostatic Expansion Valve. HFC refrigerants and POE lubricants will affect elastomeric materials in a similar fashion. R-449A does exhibit “glide”, the glide with R-448A/R-449A is approximately 8°F, please see PT Chart below for setting Cut-in and Cut-out pressures. 0 psia) Critical Temperature 81. Changed R404A system to R449A : r/refrigeration. Temperature and pressure chart for refrigerants R22, R410A, R12, R134A, R401A, R409A, R502, R404A, R507A, R408A and R402A. In the past a lot of smaller or bigger cooling furniture and a huge cooling house (-22 degrees Celsius) were fed by the rack. PDF Pressure Temperature Charts. 1 102; Saturation Pressure-Temperature Data for R22 (psig)* Temp (°F. Pressure-Temperature Chart Properties of the new zeotropic refrigerant blends are different than traditional refrigerants, it is useful to know how to read a two-column PT chart. >Pressure Temperature Chart. They have been introduced as temporary replacements for CFCs and are also greenhouse gases. Temp (°F) Pressure Temp (°C) Temp (°F) Pressure Temp (°C) Temp (°F) Temp (°C) Pressure Temp (°F) Pressure Temp (°C). Any seals that are disturbed during retrofit should be replaced with fresh parts. Opteon™ XP10 (R-513A) refrigerant is a non-ozone depleting potential (ODP), low global warming potential (GWP) hydrofluoroolefin (HFO) based replacement for R-134a. Temp (°F) R-22 R-407C Liquid Pressure R-407C Vapor Pressure R-410A Liquid Pressure R-427A Liquid Pressure R-427A Vapor Pressure R-407A Liquid. The following should be recorded as a minimum with R404A/R507 still in the system:. Mineral oil lubricants, such as 3GS, must. 06 C P/T Chart R-601 Charging & Diagnostic HVAC Buddy® Make your job easier with our handy refrigerant charging & diagnostic HVAC app. P-h Chart Download – Metric Units. Temperatures - Temperature and pressure diagram for constant boiling refrigerants - imperial and SI units. An R-22 Refrigerant Replacement for Direct Expansion Refrigeration. R 449a Pt ChartR448a PT Chart: Pressures At -49°F To 150°F Temperatures (+PDF) by R448a PT chart is quite useful in HVAC. R-449A APPLICATIONS: Low Temperature Refrigeration Medium Temperature Refrigeration PERFORMANCE: In R-22 Applications Higher System Pressures Lower Discharge Temperature Existing TXV is suitable (some adjustment will be required) Change lubricant to POE per manufacturer’s instructions Physical Properties of Refrigerants. Technicians can download the Forane ® PT App (found in iTunes and GooglePlay), containing all Forane refrigerants (see QR codes below). Scroll down to find download buttons for pressure enthalpy charts in either Metric or Imperial Units. File Type: pdf. R-449A XP40 Opteon Refrigerant PT Chart April 21, 2020 by Alec Johnson One of the very first steps when it comes to diagnosing your home air conditioner, refrigerator, or even your vehicle’s air conditioner is understanding the temperature and the current pressure that your system is operating at. • A long-term, sustainable solution is needed. Pressure Temperature Chart: R-449A Best for use in: Used in low and medium temperature commercial refrigeration systems to replace R-22, R-404A, or R-507. R22 Pressure-Temperature Chart-49-45: 1-17. Single-component refrigerants and azeotropes. Colours show AHRI GUIDELINE N-1995 refrigerant container colour assignment. Opteon™ XL20 allows much higher charge sizes than other highly flammable refrigerants. Pressure-Temperature Chart Properties of the new zeotropic refrigerant blends are different than traditional refrigerants, it is useful to know how to read a two-column PT chart. Benefits include: A low GWP of 238 (94% reduction vs. Solstice® N40 (R-448A) is a nonflammable, reduced-GWP HFO blend for new supermarkets or R-404A retrofits, especially low- and medium-temp refrigeration. 3 software (available on-line), whilst the glide comparison has “Refrigerants PT chart EU. This refrigerant allows for larger refrigerant charges compared to highly flammable ASHRAE A3 classified refrigerants (check local regulations and standards). A1 Safety Rating from ASHRAE R-449B – Blend of R-32, R-125, R-134a, and R-1234yf GWP of 1,296 A1 Safety Rating from ASHRAE Also, like before with the air conditioners these new refrigerants would have use restrictions. Forane® Refrigerant Pressure Temperature Chart. ASHRAE Number R-449A Composition R-32/R-125/HFO-1234yf/R-134a Weight % 24. com>R290 Pressure Temperature Chart. R-32 (26%), R-125 (26%), R-134a (21%), R-1234yf (20%), R-1234ze (7%) Difluoromethane, Pentafluoroethane, 1,1,1,2-Tetrafluoroethane,2,3,3,3-Tetrafluoroprop-1-ene. R-404A) Zero ozone depletion potential Improved capacity and efficiency compared to R-404A. Physical properties of R-449A and R-22. PDF R449A (XP40) Pressure Temperature Chart. R407A, R407F, R448A, R449A pressure temperature chart R407A, R407F, R448A or R449A refrigerant 1. Some of the zeotropic blends have very low glide (from 1˚F to 2. Forane® Refrigerant Pressure Temperature Chart. 6 lbs/ft 3: Liquid Density at 80°F. Pressure Temperature Chart: R-449A Best for use in: Used in low and medium temperature commercial refrigeration systems to replace R-22, R-404A, or R-507. For new equipment and retrofits. Forane Refrigerant Pressure Temperature Chart. Refrigerants - Saturation Pressures vs. R-404A, results from thermodynamic modeling, calorimeter tests, and system test suggest that R-449A may work well as a replacement for R-22. Name: R449A: Type: Blend: Class: HFO: Lubricant: POE: Liquid Density at 0°F: 78. R-449A vapours are heavier than the air, so tend to accumulate near the floor. They have been assigned an A1 safety classification under ASHRAE 34 and EN 378 standards. This refrigerant allows for larger refrigerant charges compared to highly flammable ASHRAE A3 classified refrigerants (check local regulations and standards). Features and Benefits Freon™ NU-22B™ has an ASHRAE A1 classification and is non-ozone depleting and nonflammable. Opteon™ XL10 (R-1234yf) Refrigerant. PHYSICAL PROPERTIES UNITS R-449A Molecular weight (g/mol) 87,2 Boiling point (at 1,013 bar) (ºC) -46,0 Critical temperature (ºC) 81,5 Critical pressure (bar) 44,5 Vapour pressure (25ºC) (bar) 12,75 Liquid density (21,1ºC) (Kg/m3) 1113,3 Sliding temperature or glide (K) ̴ 4 Flammability No ODP - 0 GWP - 1397 *. Excellent low-GWP, highly energy efficient and non-flammable refrigerant for low and medium temperature in commercial refrigeration: supermarket systems, vending machines (plug-ins) and other applications. Pages: 1 Page(s) Pressure Temperature Sample Chart. HVAC Buddy® Make your job easier with our handy refrigerant pressure temperature HVAC app. Designed to be suitable for all refrigeration applications, Forane ® 449A (XP40) is a four-component refrigerant with a very low boiling temperature. *Red Italics Indicate Inches of Mercury Below Atmospheric Pressure Saturation Pressure-Temperature Data for R404A (psig)*. Opteon™ XP40 Pressure-Temperature Data (Eng) P (psig ) Sat Liq T (°F) Sat Vap T (°F) P (psig ) Sat Liq T (°F) Sat Vap T (°F) P (psig ) Sat Liq T (°F) Sat Vap T (°F)-4. Opteon™ XP40 (R-449A) refrigerant is an environmentally sustainable, non-ozone depleting refrigerant offering a low global warming potential (GWP) and a superior R-507 replacement. Opteon™ XP40 Pressure-Temperature Data (Eng) P (psig ) Sat Liq T (°F) Sat Vap T (°F) P (psig ) Sat Liq T (°F) Sat Vap T (°F) P (psig ) Sat Liq T (°F) Sat Vap T (°F)-4. Forane® 427A retrofit guides. R410A Pressure-Temperature Chart For Degrees Of Celsius (°C) As you can, the pressure at a specific temperature is usually given in 3 different units: barA. Forane® 427A Refrigerant (R-427A) was commercialized in 2005 to supply the growing demand in Europe for an R-22 retrofit. Although R-448A/R-449A does exhibit “glide”, the glide with R-448A/R-449A is approximately 8°F, please see PT Chart below for setting Cut-in and Cut-out pressures. Engineering ToolBox>Refrigerants. Just check the R404A PT chart below and you will see that the pressure of 404A liquid at 85°F is 189. If the actual refrigerant temperature is 98°F, the liquid is sub-cooled 10°F. R-32 (26%), R-125 (26%), R-134a (21%), R-1234yf (20%), R-1234ze (7%) Difluoromethane, Pentafluoroethane, 1,1,1,2-Tetrafluoroethane,2,3,3,3-Tetrafluoroprop-1-ene. 8 105; Saturation Pressure-Temperature Data for R134A (psig)* Temp (°F) Pressure Temp (°C) Temp (°F) Pressure Temp (°C) Temp (°F) Pressure Temp (°C. 38% in comparison to R-404A. Pressure Temperature Chart. 7 °F) Critical Pressure 4447 kPa [abs] (655. C R AC K L ow S uction P re SS ure L ow S uP er H eat POSSIBLE CAUSES 1. Temp (°F) R-22 R-407C Liquid Pressure R-407C Vapor Pressure R-410A Liquid Pressure R-427A. Global warming is the challenge for this century, therefore Arkema introduced Forane ® 449A (XP40) as the latest fluorinated retrofit refrigerant for R-22 and R-404A with a moderate GWP of 1282. It tells you what is the pressure of R488a liquid and vapor refrigerant from -49°F to 150°F. R449A is a 4-component blend consisting of R32, R125, R134a and the HFO R1234yf. R449A (XP40) Pressure Temperature Chart R449A (XP40) Pressure Temperature Chart R449A (XP40) Pressure Temperature Chart The information contained within this website is for guidance only, for further system specific advice please call A-Gas directly. Common Alternative: R-22, R-404A, R-507 Container Sizes (lbs. Opteon™ XP40 (R-449A) refrigerant is an environmentally sustainable, non-ozone depleting refrigerant offering a low global warming potential (GWP) and a superior R-507 replacement. PHYSICAL PROPERTIES UNITS R-449A Molecular weight (g/mol) 87,2 Boiling point (at 1,013 bar) (ºC) -46,0 Critical temperature (ºC) 81,5 Critical pressure (bar) 44,5 Vapour pressure (25ºC) (bar) 12,75 Liquid density (21,1ºC) (Kg/m3) 1113,3 Sliding temperature or glide (K) ̴ 4 Flammability No ODP - 0 GWP - 1397 *. PT Chart Index Charts use °F and psig. C R AC K L ow S uction P re SS ure L ow S uP er H eat POSSIBLE CAUSES 1. iOS Android R-601 Pressure Temperature HVAC Buddy® Make your job easier with our handy refrigerant pressure temperature. (Opteon™️ XP40) GWP: 1,397 IPCC 4th Revision Application: R404A Replacement Preferred Oil: POE Ashrae Class: A1 Composition: 25. *Red Italics Indicate Inches of Mercury Below Atmospheric Pressure Saturation Pressure-Temperature Data for R404A (psig)*. Name: R449A: Type: Blend: Class: HFO: Lubricant: POE: Liquid Density at 0°F: 78. Global Warming Potential (CO2 = 1. The standard atmospheric pressure of 101,3 Pa or 14,7 psi is used. Undersized valve PRESSURE-TEMPERATURE CHART at Sea Level. R-449A – Blend of R-134a, R-1234yf, R-125, and R-32 GWP of 1,282. At 120°F, the pressure of R290 refrigerant exceeds 200 psig. It can be used as a replacement for: R-502 R-402 R-403 R-408. This paper will report the results of an extensive study investigating the performance of R-449A relative to. Name: R449A: Type: Blend: Class: HFO: Lubricant: POE: Liquid Density at 0°F: 78. If you look at a PT chart, the relationship is much closer between these refrigerants, compared to 404/507. Just check the R404A PT chart below and you will see that the pressure of 404A liquid at 85°F is 189. TEMP PRESSURE TEMP PRESSURE psig °F psig -44 0 84 137. • A new system is being installed. Mineral oil lubricants, such as 3GS, must not be used as the compressor lubricant with R-448A/ R-449A. R-22 at low-temperature conditions. DuPont™ ISCEON® M099™ refrigerant Pressure-Temperature Chart Author: DuPont Fluoroproducts Subject: Product Literature Keywords: dupont,fluoroproducts,isceon mo99,isceon,mo99,refrigerant,refrigerants,pressure temperature,r-438a,r438a Created Date: 9/11/2009 8:55:13 AM. Product Information Opteon™ XP40 (R-449A) is a non-ozone depleting, low global warming potential (GWP), hydrofluoro-olefin (HFO)- based refrigerant with an optimal balance of properties to replace R-404A/R-507, R-22, or R-407 series in positive displacement, direct expansion, low- and medium-temperature commercial and industrial applications. Solstice® N40 (R-448A) is a nonflammable, reduced-GWP HFO blend for new supermarkets or R-404A retrofits, especially low- and medium-temp refrigeration. Pressure Temperature Charts. R-449A CHEMICAL PRODUCT AND COMPANY IDENTIFICATION PRODUCT NAME: OTHER NAME:USE:DISTRIBUTOR: R-449A Refrigerant 449A Refrigerant National Refrigerants, Inc. EPA Proposes A2L Refrigerants for Air Conditioners. R-449A XP40 Opteon Refrigerant PT Chart. Opteon™ XP40 (R449A) has been successfully used in a wide range of commercial refrigeration applications. PDF DATA SHEET TECHNICAL R. Forane ® 449A (XP40) can be used for refrigeration (left side of the chart) or heating (right side of the chart). Pressure Temperature Chart: R-449A Best for use in: Used in low and medium temperature commercial refrigeration systems to replace R-22, R-404A, or R-507. A1 means that the substance is classified “non-dangerous” with the following nomenclature. R-407C chart, 250 psig is = 108°F saturated liquid temperature. For these blends, the vapor and liquid pressures are only separated by 1 or 2 psi. R449A Pressure Enthalpy Chart. R-448A N40 Refrigerant PT Chart June 29, 2020 by Alec Johnson One of the very first steps when it comes to diagnosing your home air conditioner, refrigerator, or. Opteon™ XP40 Pressure-Temperature Data (Eng) P (psig ) Sat Liq T (°F) Sat Vap T (°F) P (psig ) Sat Liq T (°F) Sat Vap T (°F) P (psig ) Sat Liq T (°F) Sat Vap T (°F)-4. *Red Italics Indicate Inches of Mercury Below Atmospheric Pressure Saturation Pressure-Temperature Data for R404A (psig)*. Features and Benefits Freon™ NU-22B™ has an ASHRAE A1 classification and is non-ozone depleting and nonflammable. R-449A will have similar capacity to R-404A (or similar) refrigerants. Pressure Temperature Charts – Hudson Technologies Pressure Temperature Charts Please select a refrigerant via the drop down menu to display pressure/temperature data. Critical Pressure (psia) 655. Opteon™ XL refrigerants provide very low GWP solutions that are specifically developed to enable new, energy efficient equipment. R-407C chart, 250 psig is = 108°F saturated liquid temperature. Even with older superheat controllers that dont have 448/449 in the programming, the OEM has instructed to set them for R22 instead - just measure and verify/set superheat afterwards. Downloads as a PDF These charts were provided courtesy of. PT Chart Index>Refrigeration Basics. Blended gases have two columns: Vapor and liquid. This blend combines HFC and HFO components that produces a lower GWP than traditional HFC products. Molecular Weight; 87. R407A, R407F, R448A and R449A have a temperature glide between 3K and 6K. R404A PT Chart: Pressure Temperature Chart For. R-449A APPLICATIONS: Low Temperature Refrigeration Medium Temperature Refrigeration PERFORMANCE: In R-22 Applications Higher System Pressures Lower Discharge Temperature Existing TXV is suitable (some adjustment will be required) Change lubricant to POE per manufacturer’s instructions Physical Properties of Refrigerants. It has a low global warming potential (GWP). Temp (°F) R-22 R-407C Liquid Pressure R-407C Vapor Pressure R-410A Liquid Pressure R-427A Liquid Pressure R-427A Vapor Pressure R-407A Liquid Pressure R-123 R-12 R-134a R-409A. R449A (XP40) Pressure Temperature Chart R449A (XP40) Pressure Temperature Chart R449A (XP40) Pressure Temperature Chart The information contained within this website is for guidance only, for further system specific advice please call A-Gas directly. Guidelines for Utilization of R. With a global warming potential (GWP) of 148, the non-ozone depleting, hydrofluoroolefin (HFO) based Opteon™ XL20 (R-454C) refrigerant offers similar performance to the refrigerants—like R-404A and R-22—it was designed to replace. = Low toxicity = No flame propagation at 18°C / 64. R449a is a mixture of common hydrofluorocarbons (HFC) and new hydrofluoro-olefin molecule R1234yf (HFO), a composition of R32 (24%), R125 (25%), R134a (26%), and R1234yf (25%) gases. Pressure Temperature (P/T) Chart: All refrigerants have a respective P/T chart. Opteon™ XP40 (R-449A) refrigerant is an environmentally sustainable, non-ozone depleting refrigerant offering a low global warming potential (GWP) and a superior R-507. TECHNICAL DATA SHEET R-449A Physical properties According to IPPCC-AR4/CIE (Fourth Assessment Report of the Intergovernmental Panel of Experts on Climate. ASHRAE Number R-449A Composition R-32/R-125/HFO-1234yf/R-134a Weight % 24. Refrigeration applications for the food industry includes supermarkets, commercial low-temperature refrigeration, as well as stand-alone or cold storage. • PT Charts (Pressure / Temperature) • Find a Superheat target using psychometric calculations • For use with R-22, R-410A, R-32, R-407C, R-134a, R-452B, R-454B, R-438A, R-422B, R-427A, R-421A, R-404A, R-290, R-449A, R-448A, and R-407A • Imperial and Metric Support. 661 Kenyon Avenue Bridgeton, New Jersey 08302 FOR MORE INFORMATION CALL: (Monday-Friday, 8:00am-5:00pm) IN CASE OF EMERGENCY CALL:. Record baseline data on original system R404A/R507 performance with the system operating under stable conditions. If the lubricant is contaminated or an acid test indicates high levels of acidity, then a lubricant change is required. R-404A, results from thermodynamic modeling, calorimeter tests, and system test suggest that R-449A may work well as a replacement for R-22. R-427A has a similar capacity, efficiency, and mass-flow rate to R-22, making it an easy retrofit option for large, medium, and small air-conditioning and refrigeration systems. Polyolester lubricant in use with R404A/R507 is suitable for use with R407A, R407F, R448A and R449A. Refrigerant Changeover Guidelines HFC R. Downloads as a PDF These charts were provided courtesy of Danfoss, using their FREE CoolSelector 2 software. R449A (XP40) Pressure Temperature Chart R449A (XP40) Pressure Temperature Chart R449A (XP40) Pressure Temperature Chart The information contained within this. Benefits include: For Forane ® 427A retrofit stickers, please call customer service at (800) 245-5858 , press 0 (North America only). EPA Proposes A2L Refrigerants for Air Conditioners>EPA Proposes A2L Refrigerants for Air Conditioners. Product Information Opteon™ XP40 (R-449A) is a non-ozone depleting, low global warming potential (GWP), hydrofluoro-olefin (HFO)- based refrigerant with an optimal balance of. It is compatible with POE synthetic oils. R-449A is intended for use in low and medium temperature refrigeration systems to replace R-22, R-404A or R-507. R134A Pressure-Temperature Chart-49-45: 1-17. This blend combines HFC and HFO components that produces a lower GWP than traditional HFC products. R-449A XP40 Opteon Refrigerant PT Chart April 21, 2020 by Alec Johnson One of the very first steps when it comes to diagnosing your home air conditioner,. Refrigerants - Pressure vs. AHRI is now specifing that all refrigerant containers should have one uniform paint color, grey RAL 7044 and that the previously assigned colors should be transitioned. Critical Pressure (psia) 655. 4 Solstice N40 (R-448A) provides better capacity* than R-449A 4 Due to lower Tdis at the conditions shown Comparison and results for efficiency, capacity and discharge temperature in the charts above have been generated using Bitzer v6. A Leading HFC Refrigerant Replacement Freon™ MO79 (R-422a) refrigerant is a non-ozone depleting hydrofluorocarbon (HFC) refrigerant and one of the leading alternatives used to replace hydrochlorofluorocarbon (HCFC) blends. Download for free our refrigerant system simulation tool which makes it easier than ever to select the right refrigerant. 427A (R427A) retrofit guidelines. 5 psig and the pressure of 404A vapor is 187. Compositions of Refrigerant Blends. Pressure Temperature Chart: R-449A Best for use in: Used in low and medium temperature commercial refrigeration systems to replace R-22, R-404A, or R-507. Talk with the developers of HVAC Buddy® and 1,000s of other HVAC professionals and hobbyists that use our apps. Designed to be suitable for all refrigeration applications, Forane ® 449A (XP40) is a four-component refrigerant with a very low boiling temperature and. Opteon™ XP40 Pressure-Temperature Data (Eng) P (psig ) Sat Liq T (°F) Sat Vap T (°F) P (psig ) Sat Liq T (°F) Sat Vap T (°F) P (psig ) Sat Liq T (°F) Sat Vap T (°F)-4. 3% R32 Available Cylinder Sizes 9/46 Kg Cyl See our short video guide to R449A. Inversely, you can also tell the temperature of R488a refrigerant if you know the pressures (from 0. TEMP PRESSURE TEMP PRESSURE psig °F psig -44 0 84 137. SI Charts are available for SI Boards. Engineering ToolBox - Resources, Tools and Basic Information for Engineering and Design of Technical Applications! Refrigerants - Pressure vs. Now there’s only the cooling house left. R449A, Blend, HFO. R-449A (XP40) is an HFO-based refrigerant blend that was initially developed as a replacement for high GWP HFC blends like R-404A/R-507, but now is being investigated as a potential R-22 alternative in refrigeration applications as well. A Leading HFC Refrigerant Replacement Freon™ MO79 (R-422a) refrigerant is a non-ozone depleting hydrofluorocarbon (HFC) refrigerant and one of the leading alternatives used to replace hydrochlorofluorocarbon (HCFC) blends. R-404A and R-507 Up to 8% improved cooling capacity and up to 14% improved efficiency vs. Global warming is the challenge for this century, therefore Arkema introduced Forane ® 449A (XP40) as the latest fluorinated retrofit refrigerant for R-22 and R-404A with a moderate GWP of 1282. 661 Kenyon Avenue Bridgeton, New Jersey 08302 FOR MORE INFORMATION CALL: IN CASE OF EMERGENCY CALL:. Common Alternative: R-22, R-404A, R-507 Container Sizes (lbs. Forane ® 427A (R427A) is the ideal R22 retrofit for air conditioning, heat pumps, and refrigeration applications. R-449A 4 Solstice N40 (R-448A) provides better capacity* than R-449A 4 Due to lower Tdis at the conditions shown, Solstice N40 (R-448A)does not require liquid injection in low temperature applications – unlike R-407F and R-407A -10oC-10oC / /45oC 45oC -10oC-10oC / /45oC 45oC -30oC-30oC / /45oC 45oC. It is well-suited for AC applications because it closely mimics the operating characteristics of R-22 and works over the same operating pressures as R-22. THERMODYNAMIC PROPERTIES AND CYCLE MODELS A comparison of the basic physical properties of R-449A and R-22 are shown below in Table 1. R449A has a significantly lower GWP (1,397) than R404A and has been classified by Ashrae as A1 non-flammable and is suitable for new as well as retrofitting existing R404A systems. R449A (XP40) Pressure Temperature Chart R449A (XP40) Pressure Temperature Chart R449A (XP40) Pressure Temperature Chart The information contained within this website is for guidance only, for further system specific advice please call A-Gas directly. Product Information Opteon™ XP40 (R-449A) is a non-ozone depleting, low global warming potential (GWP), hydrofluoro-olefin (HFO)- based refrigerant with an optimal balance of properties to replace R-404A/R-507, R-22, or R-407 series in positive displacement, direct expansion, low- and medium-temperature commercial and industrial applications. Toxicity and storage R-449A is a substance with a very low toxicity. Pressure Temperature Charts – Hudson Technologies Pressure Temperature Charts Please select a refrigerant via the drop down menu to display pressure/temperature data. We recently changed a R404A rack (3 pieces of 6 cylinder Bitzer compressors) to R449A without changing the Thermostatic Expansion Valve. Used in applications like: food service, cold storage, supermarkets, ice rink systems, walk-in coolers/freezers. Overview Properties SKUs Resources Save this page as PDF Contact us SDS Finder. Opteon™ XP40 Pressure-Temperature Data (Eng) P (psig ) Sat Liq T (°F) Sat Vap T (°F) P (psig ) Sat Liq T (°F) Sat Vap T (°F) P (psig ) Sat Liq T (°F) Sat Vap T (°F)-4. R448a PT Chart: Pressures At -49°F To 150°F Temperatures (+PDF) by R448a PT chart is quite useful in HVAC. 508B (R-508B) A non-ozone depleting azeotrope of R-23 and R-116 used to replace R-13 and R-503 in the low stage of cascade systems. This nonflammable HFC alternative offers a host of benefits that include: Cost-effective retrofits (and easier retrofitting) than R-404A, R-507, and R-407C A 30% lower GWP vs. Temperature Charts - Temperature and pressure chart for refrigerants R22, R410A, R12, R134A, R401A, R409A, R502, R404A, R507A, R408A and R402A. Pressure Temperature Charts – Hudson Technologies. If you are working in HVAC, having the R290 PT chart on hand will help in several tasks, including:. Heat of Vaporization ( bp,BTU/lb. R290 PT Chart: Pressures At. An R-22 Refrigerant Replacement for Direct Expansion Refrigeration. Product Information Opteon™ XP40 (R-449A) is a non-ozone depleting, low global warming potential (GWP), hydrofluoro-olefin (HFO)- based refrigerant with an optimal balance of properties to replace R-404A/R-507, R-22, or R-407 series in positive displacement, direct expansion, low- and medium-temperature commercial and industrial applications. Select a Refrigerant 300 Tice Boulevard, Suite 290, Second Floor Woodcliff Lake, NJ 07677 © 2022 Hudson Technologies, All Rights Reserved REQUEST A QUOTE CAREERS. Undersized valve PRESSURE-TEMPERATURE CHART at Sea Level. You can download that software free of charge also using this link. Choose Opteon™ XL products when: • The existing system is too old for a retrofit. Known as “ absolute pressure “; pressure against a perfect vacuum. Pages: 1 Page(s) Pressure Temperature Sample Chart. Compatible with traditional and new lubricants, including mineral (MO), alkylbenzene (AB), and polyolester (POE) oils, most systems retrofitting to Freon. R449A Pressure Enthalpy Chart. It can also be used to retrofit R-22-based blends such as R-402A/B and R-408A. R-404A, and R-452A are non-flammable. PT charts for the zeotropic blends list two columns next to each temperature: one for the saturated liquid (bubble point) and the other for the saturated vapor (dew point). R448a PT Chart: Pressures At. R-448A N40 Refrigerant PT Chart June 29, 2020 by Alec Johnson One of the very first steps when it comes to diagnosing your home air conditioner, refrigerator, or even your vehicles air conditioner is understanding the temperature and the current pressure that your system is operating at. One of the very first steps when it comes to diagnosing your home air conditioner, refrigerator, or even your vehicle’s air conditioner is understanding the temperature and the current pressure that your system is operating at. Pressure Temperature Charts – Hudson Technologies>Pressure Temperature Charts – Hudson Technologies. CHEMICAL PRODUCT AND COMPANY IDENTIFICATION PRODUCT NAME: R-449A OTHER NAME: Refrigerant 449A USE: Refrigerant DISTRIBUTOR: National Refrigerants, Inc. Opteon™ XP40 (R449A) has been successfully used in a wide range of commercial refrigeration applications. The R290 pressure temperature chart starts at the boiling point temperature of 44°F (0 psig).